{"id":244,"date":"2026-10-23T16:25:32","date_gmt":"2026-10-23T10:55:32","guid":{"rendered":"https:\/\/incepbio.com\/blog\/?p=244"},"modified":"2026-10-23T17:02:53","modified_gmt":"2026-10-23T11:32:53","slug":"computer-system-validation-process","status":"publish","type":"post","link":"https:\/\/incepbio.com\/blog\/computer-system-validation-process\/","title":{"rendered":"Computer System Validation Process: 7 Key Steps for GMP Compliance"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"244\" class=\"elementor elementor-244\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0b06257 e-flex e-con-boxed e-con e-parent\" data-id=\"0b06257\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-71b312d elementor-widget elementor-widget-text-editor\" data-id=\"71b312d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<div style=\"width:100%;margin:30px 0;background:linear-gradient(135deg,#E3F3F0 0%,#F3F8FC 100%);border:1px solid #CFE5E0;border-radius:12px;padding:7px;font-family:inherit\">\n\n  <div style=\"background:#FFFFFF;border-radius:8px;padding:26px 28px\">\n\n    <div style=\"display:flex;align-items:center;gap:12px;margin-bottom:21px\">\n      <div style=\"display:flex;align-items:center;justify-content:center;flex-shrink:0;width:40px;height:40px;background:linear-gradient(145deg,#00A596,#00796F);border-radius:10px\">\n        <span style=\"color:#FFFFFF;font-size:22px;font-weight:700\">\u2713<\/span>\n      <\/div>\n      <div>\n        <p style=\"margin:0 0 4px;color:#008477;font-size:12px;font-weight:800;letter-spacing:1.3px\">QUICK ANSWER<\/p>\n        <p style=\"margin:0;color:#71817E;font-size:13px\">Computer System Validation (CSV)<\/p>\n      <\/div>\n    <\/div>\n\n    <h2 style=\"margin:0 0 14px;color:#173F3B;font-size:24px;line-height:1.4;font-weight:700\">\n      What Is the Computer System Validation Process?\n    <\/h2>\n\n    <p style=\"margin:0;color:#405652;font-size:16px;line-height:1.85\">\n      The computer system validation process is a documented, risk-based approach to demonstrating that a computerized system performs as intended and meets applicable GMP and business requirements.\n    <\/p>\n\n    <div style=\"margin-top:24px;padding:18px;background:linear-gradient(110deg,#E7F5F2,#F2F8F7);border:1px solid #D5E9E4;border-radius:7px\">\n      <p style=\"margin:0 0 10px;color:#173F3B;font-size:13px;font-weight:800;letter-spacing:0.8px\">\n        <span style=\"color:#009C8D\">|<\/span>&nbsp; KEY STAGES\n      <\/p>\n      <p style=\"margin:0;color:#315C55;font-size:14px;line-height:2\">\n        Planning <span style=\"color:#009C8D;font-weight:700\">\u2192<\/span>\n        Requirements <span style=\"color:#009C8D;font-weight:700\">\u2192<\/span>\n        Risk Assessment <span style=\"color:#009C8D;font-weight:700\">\u2192<\/span>\n        Testing <span style=\"color:#009C8D;font-weight:700\">\u2192<\/span>\n        Reporting <span style=\"color:#009C8D;font-weight:700\">\u2192<\/span>\n        Ongoing Control\n      <\/p>\n    <\/div>\n\n  <\/div>\n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-de41467 e-flex e-con-boxed e-con e-parent\" data-id=\"de41467\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9ea9644 elementor-widget elementor-widget-text-editor\" data-id=\"9ea9644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<div style=\"width:100%;margin:28px 0;padding:24px 26px;background:linear-gradient(135deg,#F0F6F8 0%,#F8FAFC 100%);border:1px solid #DCE6ED;border-radius:10px;font-family:inherit\">\n\n  <div style=\"display:flex;align-items:center;gap:12px;margin-bottom:10px\">\n    <div style=\"width:40px;height:40px;flex-shrink:0;display:flex;align-items:center;justify-content:center;background:#173F3B;border-radius:8px;color:#FFFFFF;font-size:21px\">\n      \u2713\n    <\/div>\n    <h2 style=\"margin:0;color:#173F3B;font-size:23px;line-height:1.4;font-weight:700\">\n      Key Takeaways\n    <\/h2>\n  <\/div>\n\n  <p style=\"margin:0 0 20px;color:#62716F;font-size:14px;line-height:1.7\">\n    The essential points to understand about computer system validation.\n  <\/p>\n\n  <div style=\"border-top:1px solid #DCE6ED;padding-top:17px;margin-top:0\">\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;margin-bottom:17px\">\n      <span style=\"color:#009C8D;font-size:19px;line-height:1.5\">\u2713<\/span>\n      <div>\n        <p style=\"margin:0 0 4px;color:#173F3B;font-size:16px;font-weight:700\">Risk-based approach<\/p>\n        <p style=\"margin:0;color:#405652;font-size:15px;line-height:1.75\">Validation effort should reflect the system&#8217;s intended use, GxP impact, and risk.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;margin-bottom:17px\">\n      <span style=\"color:#009C8D;font-size:19px;line-height:1.5\">\u2713<\/span>\n      <div>\n        <p style=\"margin:0 0 4px;color:#173F3B;font-size:16px;font-weight:700\">Documented evidence<\/p>\n        <p style=\"margin:0;color:#405652;font-size:15px;line-height:1.75\">Requirements, risk assessments, test results, and approvals provide evidence that the system works as intended.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px\">\n      <span style=\"color:#009C8D;font-size:19px;line-height:1.5\">\u2713<\/span>\n      <div>\n        <p style=\"margin:0 0 4px;color:#173F3B;font-size:16px;font-weight:700\">Lifecycle control<\/p>\n        <p style=\"margin:0;color:#405652;font-size:15px;line-height:1.75\">Changes, access, incidents, and periodic reviews help maintain the validated state.<\/p>\n      <\/div>\n    <\/div>\n\n  <\/div>\n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d60afe9 e-flex e-con-boxed e-con e-parent\" data-id=\"d60afe9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7365746 elementor-widget elementor-widget-text-editor\" data-id=\"7365746\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<div style=\"margin:24px 0 30px;font-family:inherit\">\n  <h2 style=\"margin:0 0 14px;color:#173F3B;font-size:21px;line-height:1.4;font-weight:700\">\n    In This Article\n  <\/h2>\n\n  <div style=\"border-left:2px solid #009C8D;padding-left:16px\">\n    <p style=\"margin:0 0 10px\"><a href=\"#why-csv-matters\" style=\"color:#007F73;text-decoration:none\">Why CSV Matters<\/a><\/p>\n    <p style=\"margin:0 0 10px\"><a href=\"#csv-regulations-guidance\" style=\"color:#007F73;text-decoration:none\">Regulations Versus Guidance<\/a><\/p>\n    <p style=\"margin:0 0 10px\"><a href=\"#csv-seven-steps\" style=\"color:#007F73;text-decoration:none\">The 7 Steps<\/a><\/p>\n    <p style=\"margin:0 0 10px\"><a href=\"#csv-documentation\" style=\"color:#007F73;text-decoration:none\">Documentation<\/a><\/p>\n    <p style=\"margin:0 0 10px\"><a href=\"#maintaining-validated-state\" style=\"color:#007F73;text-decoration:none\">Maintaining the Validated State<\/a><\/p>\n    <p style=\"margin:0\"><a href=\"#csv-faqs\" style=\"color:#007F73;text-decoration:none\">FAQs<\/a><\/p>\n  <\/div>\n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3ba30f3 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"3ba30f3\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"3ba30f3\">\n    \t\t\t<p class=\"e-afe3753-c68748d e-paragraph-base e-default-p\" data-interaction-id=\"afe3753\">Laboratory systems, batch record platforms, and PLCs can each affect product quality or data integrity, so regulators expect evidence that they work as intended. The computer system validation process provides that evidence. This guide explains seven practical steps, key documents, and how to keep systems validated.<br><\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-8c65341 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"8c65341\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"8c65341\">\n    \t\t\t<h2 data-interaction-id=\"e3ac31d\" class=\"e-heading-base e-default-h2\"><strong>Why GMP Computer System Validation Matters<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-bed7863 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"bed7863\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"bed7863\">\n    \t\t\t<p class=\"e-7f5743f-53851ac e-paragraph-base e-default-p\" data-interaction-id=\"7f5743f\">Computerized systems create, process, and store GxP records. If a system calculates incorrectly or allows untraceable changes, release decisions rest on unreliable data.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-8483038 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"8483038\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"8483038\">\n    \t\t\t<h2 data-interaction-id=\"d46533f\" class=\"e-heading-base e-default-h2\"><strong>Regulations Versus Guidance<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-8d6c5ea e-flex e-con-boxed e-con e-parent\" data-id=\"8d6c5ea\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9b69bf1 elementor-widget elementor-widget-text-editor\" data-id=\"9b69bf1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p style=\"font-family:inherit;font-size:16px;line-height:1.8;color:inherit\">\n  Requirements differ by region and by system. In the US,\n  <a href=\"https:\/\/www.ecfr.gov\/current\/title-21\/chapter-I\/subchapter-A\/part-11\" style=\"color:#009C8D;text-decoration:underline\" target=\"_blank\" rel=\"noopener\">21 CFR Part 11<\/a>\n  applies to electronic records and signatures that fall within its scope, and FDA\u2019s\n  <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/part-11-electronic-records-electronic-signatures-scope-and-application\" style=\"color:#009C8D;text-decoration:underline\" target=\"_blank\" rel=\"noopener\">scope and application guidance<\/a>\n  explains how the agency approaches it. For drug manufacturing,\n  <a href=\"https:\/\/www.ecfr.gov\/current\/title-21\/chapter-I\/subchapter-C\/part-211\" style=\"color:#009C8D;text-decoration:underline\" target=\"_blank\" rel=\"noopener\">21 CFR Part 211<\/a>\n  includes \u00a7211.68 on automatic, mechanical, and electronic equipment, but its provisions do not apply identically to every system.\n<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-81841a2 e-flex e-con-boxed e-con e-parent\" data-id=\"81841a2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9efcd2 elementor-widget elementor-widget-text-editor\" data-id=\"a9efcd2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p style=\"font-family:inherit;font-size:16px;line-height:1.8;color:inherit\">\n  In the EU, EU GMP Annex 11 is relevant to computerised systems used in GMP-regulated activities, and Annex 15 covers qualification and validation (see\n  <a href=\"https:\/\/health.ec.europa.eu\/medicinal-products\/eudralex\/eudralex-volume-4_en\" style=\"color:#009C8D;text-decoration:underline\" target=\"_blank\" rel=\"noopener\">EudraLex Volume 4<\/a>).\n  The European Commission released a draft revision of Annex 11 for public consultation in 2025. The consultation closed on 7 October 2025; the current published Annex 11 remains listed as the January 2011 revision. GAMP 5 from ISPE is industry guidance that supports a risk-based approach but does not replace applicable regulations.\n<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-01b636c e-flex e-con-boxed e-con e-parent\" data-id=\"01b636c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c277ff elementor-widget elementor-widget-text-editor\" data-id=\"2c277ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p style=\"font-family:inherit;font-size:16px;line-height:1.8;color:inherit\">\n  CSV and CSA are related but are not interchangeable regulatory terms.\n  <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/computer-software-assurance-production-and-quality-management-system-software\" style=\"color:#009C8D;text-decoration:underline\" target=\"_blank\" rel=\"noopener\">FDA\u2019s Computer Software Assurance (CSA) guidance<\/a>\n  addresses software used in medical-device production and quality management systems. It should not be treated as a universal replacement for pharmaceutical CSV requirements.\n<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6655376 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"6655376\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"6655376\">\n    \t\t\t<h2 data-interaction-id=\"80d5397\" class=\"e-heading-base e-default-h2\"><strong>The 7 Key Steps in the Computer System Validation Process<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-ec76c2a e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"ec76c2a\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"ec76c2a\">\n    \t\t\t<p class=\"e-a7ad3f1-3b736ef e-paragraph-base e-default-p\" data-interaction-id=\"a7ad3f1\">Treat these steps as a practical, risk-based lifecycle model. They are not a legally mandated sequence, and companies adapt them to their quality systems.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-fef4b29 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"fef4b29\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"fef4b29\">\n    \t\t\t<h3 data-interaction-id=\"206a920\" class=\"e-heading-base e-default-h3\"><strong>Step 1: Define Intended Use and Scope<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-60507ef e-flex e-con-boxed e-con e-parent\" data-id=\"60507ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b858a24 elementor-widget elementor-widget-text-editor\" data-id=\"b858a24\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<p style=\"font-family:inherit;font-size:16px;line-height:1.8;color:inherit\">\n  Start with what the system does and which processes, records, and users it touches. A stability chamber monitoring system and an ERP module used for batch release have very different scopes. For PLC-controlled equipment, coordinate computer system validation (CSV) with equipment qualification to ensure that both the equipment and its computerized control functions are assessed for their intended use. Learn more about\n  <a href=\"https:\/\/incepbio.com\/blog\/pharmaceutical-equipment-qualification\/\" style=\"color:#009C8D;text-decoration:underline\">pharmaceutical equipment qualification<\/a>.\n<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-35be841 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"35be841\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"35be841\">\n    \t\t\t<h3 data-interaction-id=\"2735137\" class=\"e-heading-base e-default-h3\"><strong>Step 2: Assess GxP Impact and Risk<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-5ce9566 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"5ce9566\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"5ce9566\">\n    \t\t\t<p class=\"e-1be80d0-2a411d3 e-paragraph-base e-default-p\" data-interaction-id=\"1be80d0\">Decide whether the system affects patient safety, product quality, or data integrity, then assess its risks. In a computer system validation risk assessment, a batch record calculation may rate high, while a report\u2019s cosmetic layout rates low. Those ratings guide testing depth.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-264eed1 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"264eed1\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"264eed1\">\n    \t\t\t<h3 data-interaction-id=\"9c6dc71\" class=\"e-heading-base e-default-h3\"><strong>Step 3: Establish Requirements and Plan Validation<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-c6c3765 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"c6c3765\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"c6c3765\">\n    \t\t\t<p class=\"e-2f4c3e3-2ea2586 e-paragraph-base e-default-p\" data-interaction-id=\"2f4c3e3\">Write user requirements that are clear, testable, and tied to intended use. For a laboratory system, examples include unique logins and audit trails for result changes. Then prepare a validation plan covering roles, deliverables, test approach, and acceptance criteria.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-c794e91 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"c794e91\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"c794e91\">\n    \t\t\t<h3 data-interaction-id=\"02da100\" class=\"e-heading-base e-default-h3\"><strong>Step 4: Review Supplier Documentation and Specifications<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-99b9186 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"99b9186\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"99b9186\">\n    \t\t\t<p class=\"e-ab59aea-2aeb9e4 e-paragraph-base e-default-p\" data-interaction-id=\"ab59aea\">Assess the supplier\u2019s quality system and, where justified, use their testing evidence rather than repeating it. Prepare functional or design specifications for configured or custom elements. Standard functions may need less testing when the risk assessment and available supplier evidence justify it.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-fb22402 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"fb22402\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"fb22402\">\n    \t\t\t<h3 data-interaction-id=\"a7f9ca3\" class=\"e-heading-base e-default-h3\"><strong>Step 5: Execute Risk-Based Testing and Record Evidence<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-c961598 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"c961598\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"c961598\">\n    \t\t\t<p class=\"e-1020e5e-7ec37ae e-paragraph-base e-default-p\" data-interaction-id=\"1020e5e\">Match testing to risk. Functions with high impact, such as electronic signatures or calculations, often justify scripted tests with predefined expected results. Lower-risk functions may be covered by lighter methods. Intended use, applicable requirements, and approved procedures should justify the depth you choose. Record actual results, who tested, and when, so an independent reviewer can reach the same conclusion.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-5b95d33 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"5b95d33\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"5b95d33\">\n    \t\t\t<h3 data-interaction-id=\"32b51b4\" class=\"e-heading-base e-default-h3\"><strong>Step 6: Manage Deviations and Maintain Traceability<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-decaad9 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"decaad9\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"decaad9\">\n    \t\t\t<p class=\"e-9e8e986-c2316de e-paragraph-base e-default-p\" data-interaction-id=\"9e8e986\">Tests sometimes fail. Record each deviation, assess its impact, correct the cause, and retest. A requirements traceability matrix shows whether every requirement has test coverage and links failures to their deviation records.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-59bd6b5 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"59bd6b5\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"59bd6b5\">\n    \t\t\t<h3 data-interaction-id=\"7372043\" class=\"e-heading-base e-default-h3\"><strong>Step 7: Prepare the Summary Report and Approve Release<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-3f585b0 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"3f585b0\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"3f585b0\">\n    \t\t\t<p class=\"e-6b03c85-bf78f12 e-paragraph-base e-default-p\" data-interaction-id=\"6b03c85\">Summarize the work, test results, deviations, and conclusion on whether the system is fit for its intended use. Obtain the required approvals under the company\u2019s quality system before releasing the system for GxP use. Confirm that required documentation is approved, deviations are closed or formally justified, users are trained, procedures are effective, and access and backup controls are in place.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-6abb180 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"6abb180\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"6abb180\">\n    \t\t\t<h2 data-interaction-id=\"3ce7ca1\" class=\"e-heading-base e-default-h2\"><strong>Computer System Validation Documentation<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-79df06a e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"79df06a\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"79df06a\">\n    \t\t\t<p class=\"e-c5e70bc-df184d0 e-paragraph-base e-default-p\" data-interaction-id=\"c5e70bc\">The documents required depend on system complexity, risk, intended use, supplier evidence, and the applicable quality system. Not every system needs the same set.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-b9fbaf5 e-flex e-con-boxed e-con e-parent\" data-id=\"b9fbaf5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-183a7fa elementor-widget elementor-widget-text-editor\" data-id=\"183a7fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<div style=\"width:100%;margin:28px 0;padding:26px 24px;background:#F3F7F8;border:1px solid #D9E5E7;border-left:5px solid #009C8D;border-radius:10px;font-family:inherit\">\n\n  <h2 style=\"margin:0 0 8px 0;padding:0;color:#173F3B;font-size:24px;line-height:1.4;font-weight:700\">\n    Core Deliverables\n  <\/h2>\n\n  <p style=\"margin:0 0 22px 0;padding:0;color:#647572;font-size:14px;line-height:1.6\">\n    Key documents and evidence required during the CSV process\n  <\/p>\n\n  <div style=\"background:#FFFFFF;border:1px solid #E2EAEB;border-radius:8px;padding:6px 18px\">\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Validation plan<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Defines the scope, approach, and responsibilities.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">User Requirements Specification (URS)<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Documents what the system must do.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Risk assessment<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Identifies risks and determines where validation effort should focus.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Functional or design specifications<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Describe system functions or design details, where applicable.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Requirements Traceability Matrix<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Connects requirements with specifications, tests, and results.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Test protocols and executed evidence<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Records test procedures, actual results, and supporting evidence.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0;border-bottom:1px solid #E8EEEE\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Deviation records<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Document issues identified during testing and how they were resolved.<\/p>\n      <\/div>\n    <\/div>\n\n    <div style=\"display:flex;align-items:flex-start;gap:12px;padding:15px 0\">\n      <span style=\"display:inline-block;flex-shrink:0;width:25px;height:25px;line-height:25px;text-align:center;background:#E3F4F1;color:#008777;border-radius:50%;font-size:14px;font-weight:700\">\u2713<\/span>\n      <div style=\"flex:1;min-width:0\">\n        <p style=\"margin:1px 0 4px;color:#173F3B;font-size:16px;line-height:1.5;font-weight:700\">Validation summary report<\/p>\n        <p style=\"margin:0;color:#52635F;font-size:15px;line-height:1.7\">Summarises the validation outcome and provides the basis for release.<\/p>\n      <\/div>\n    <\/div>\n\n  <\/div>\n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-824d83a e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"824d83a\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"824d83a\">\n    \t\t\t<h5 data-interaction-id=\"1114aba\" class=\"e-heading-base e-default-h5\"><strong>Computer System Validation Traceability Matrix<\/strong><\/h5>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-b5255de e-flex e-con-boxed e-con e-parent\" data-id=\"b5255de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1f33f4c elementor-widget elementor-widget-text-editor\" data-id=\"1f33f4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div style=\"width:100%;margin:20px 0\">\n\n  <h3 style=\"margin:0 0 12px;color:#222;font-size:22px;line-height:1.4\">\n    Example of a CSV Traceability Matrix\n  <\/h3>\n\n  <p style=\"margin:0 0 16px;color:#333;font-size:16px;line-height:1.7\">\n    A traceability matrix links each system requirement to its corresponding\n    test and recorded result. The example below illustrates how requirements\n    can be tracked during computer system validation.\n  <\/p>\n\n  <div style=\"width:100%\">\n    <table style=\"width:100%;min-width:650px;border-collapse:collapse;font-size:14px;text-align:left;color:#333\">\n      <thead>\n        <tr style=\"background:#009C8D;color:#ffffff\">\n          <th style=\"padding:12px;border:1px solid #ddd\">Requirement ID<\/th>\n          <th style=\"padding:12px;border:1px solid #ddd\">Requirement<\/th>\n          <th style=\"padding:12px;border:1px solid #ddd\">Test ID<\/th>\n          <th style=\"padding:12px;border:1px solid #ddd\">Result<\/th>\n          <th style=\"padding:12px;border:1px solid #ddd\">Deviation Reference<\/th>\n        <\/tr>\n      <\/thead>\n\n      <tbody>\n        <tr>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">URS-001<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">Only authorised users can access the system<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">TC-001<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd\">\n            <span style=\"display:inline-block;color:#166534;background:#dcfce7;padding:4px 10px;border-radius:4px;font-weight:600\">Pass<\/span>\n          <\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">None<\/td>\n        <\/tr>\n\n        <tr style=\"background:#f7f9f9\">\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">URS-002<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">Relevant user activities are recorded in the audit trail<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">TC-002<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd\">\n            <span style=\"display:inline-block;color:#166534;background:#dcfce7;padding:4px 10px;border-radius:4px;font-weight:600\">Pass<\/span>\n          <\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">None<\/td>\n        <\/tr>\n\n        <tr>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">URS-003<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">User access permissions can be assigned by role<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">TC-003<\/td>\n          <td style=\"padding:12px;border:1px solid #ddd\">\n            <span style=\"display:inline-block;color:#991b1b;background:#fee2e2;padding:4px 10px;border-radius:4px;font-weight:600\">Fail<\/span>\n          <\/td>\n          <td style=\"padding:12px;border:1px solid #ddd;color:#333\">DEV-001<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <p style=\"margin:12px 0 0;color:#666;font-size:13px;line-height:1.6\">\n    Note: This is an illustrative example, not an actual validation record.\n    Failed tests should be documented, investigated and handled according\n    to approved procedures.\n  <\/p>\n\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f364f78 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"f364f78\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"f364f78\">\n    \t\t\t<h2 data-interaction-id=\"028ca67\" class=\"e-heading-base e-default-h2\"><strong>Maintaining the Validated State<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-ff2cf55 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"ff2cf55\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"ff2cf55\">\n    \t\t\t<p class=\"e-c490996-718a490 e-paragraph-base e-default-p\" data-interaction-id=\"c490996\">Validation does not end at go-live. Change control, periodic review, access management, backup and restore checks, and incident handling keep the system in a validated state. These controls also protect data integrity. Significant changes, such as software upgrades, new interfaces, or configuration changes affecting GxP records, may call for impact assessment and targeted retesting. The review frequency should follow risk and your procedures, not a fixed calendar rule.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-32f0a47 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"32f0a47\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"32f0a47\">\n    \t\t\t<h2 data-interaction-id=\"2668abf\" class=\"e-heading-base e-default-h2\"><strong>How IncepBio Supports Computer System Validation<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-1735cfb e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"1735cfb\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"1735cfb\">\n    \t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"d0770f4\">IncepBio supports pharmaceutical companies with risk-based Computer System Validation (CSV) and Computer Software Assurance (CSA) throughout a system\u2019s lifecycle, from planning to regular reviews.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-d7570e1 e-flex e-con-boxed e-con e-parent\" data-id=\"d7570e1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-90ec4ac elementor-widget elementor-widget-text-editor\" data-id=\"90ec4ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<ul style=\"margin:12px 0 20px;padding-left:22px;color:inherit;font-family:inherit;font-size:16px;line-height:1.8\">\n  <li style=\"padding-left:4px;margin-bottom:8px\"><strong>Planning and Risk Assessment:<\/strong> Defines system requirements, reviews risks, and prepares validation plans.<\/li>\n  <li style=\"padding-left:4px;margin-bottom:8px\"><strong>Testing and Documentation:<\/strong> Supports IQ, OQ, and PQ testing, requirement tracking, and validation reports.<\/li>\n  <li style=\"padding-left:4px;margin-bottom:8px\"><strong>Compliance Checks:<\/strong> Reviews systems against 21 CFR Part 11 and EU GMP Annex 11 and identifies gaps that need attention.<\/li>\n  <li style=\"padding-left:4px;margin-bottom:8px\"><strong>Data Integrity:<\/strong> Reviews audit trails, user access, and electronic signatures to help protect data.<\/li>\n  <li style=\"padding-left:4px;margin-bottom:8px\"><strong>Supplier Assessment:<\/strong> Reviews supplier quality and available documents to plan suitable validation activities.<\/li>\n  <li style=\"padding-left:4px;margin-bottom:0\"><strong>Ongoing Support:<\/strong> Supports change control, periodic reviews, revalidation, and system retirement.<\/li>\n<\/ul>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d7b6d1 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"8d7b6d1\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"8d7b6d1\">\n    \t\t\t<h3 data-interaction-id=\"b634a51\" class=\"e-heading-base e-default-h3\"><strong>Systems Covered<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-8d4c206 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"8d4c206\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"8d4c206\">\n    \t\t\t<p class=\"e-75c80c1-f44d789 e-paragraph-base e-default-p\" data-interaction-id=\"75c80c1\">IncepBio supports validation for laboratory systems (LIMS and CDS), manufacturing systems (PLC, SCADA, HMI, DCS, and MES), enterprise systems (ERP), quality management systems (eQMS), and facility monitoring systems (BMS and EMS).<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-f05082d e-flex e-con-boxed e-con e-parent\" data-id=\"f05082d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3505484 elementor-widget elementor-widget-text-editor\" data-id=\"3505484\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"font-family:inherit;font-size:16px;line-height:1.8;color:inherit\">\n  Explore <a href=\"https:\/\/www.incepbio.com\/csa-csv\" style=\"color:#009C8D;text-decoration:underline\">IncepBio\u2019s CSV\/CSA services<\/a> to learn more.\n<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-64cf5b5 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"64cf5b5\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"64cf5b5\">\n    \t\t\t<h3 data-interaction-id=\"2625201\" class=\"e-heading-base e-default-h3\"><strong>Conclusion<\/strong><\/h3>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-fe8cec8 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"fe8cec8\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"fe8cec8\">\n    \t\t\t<p class=\"e-375d70e-35f290f e-paragraph-base e-default-p\" data-interaction-id=\"375d70e\">A reliable computer system validation process starts with clear intended use, documented requirements and a risk-based approach to testing. Pharmaceutical companies should also maintain traceable evidence, manage deviations and assess system changes throughout its lifecycle.The validation approach and documentation should reflect the system's intended use, complexity and impact on product quality, patient safety and data integrity. With appropriate planning and ongoing controls, organisations can maintain systems in a validated state and support GMP compliance.<\/p>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-3647313 e-con e-atomic-element e-flexbox-base e-default-div \" data-id=\"3647313\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"3647313\">\n    \t\t\t<h2 data-interaction-id=\"7fc3664\" class=\"e-heading-base e-default-h2\"><strong>Frequently Asked Questions<\/strong><\/h2>\n\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-1fd0727 e-flex e-con-boxed e-con e-parent\" data-id=\"1fd0727\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-18b82f7 elementor-widget elementor-widget-n-accordion\" data-id=\"18b82f7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2590\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2590\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What is the computer system validation process in pharma? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2590\" class=\"elementor-element elementor-element-ad920f4 e-con-full e-flex e-con e-child\" data-id=\"ad920f4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<p class=\"e-8939286-6ede26c e-paragraph-base e-default-p\" data-interaction-id=\"8939286\">It is a documented, risk-based process showing that a GxP computerized system performs as intended. It links intended use, requirements, testing, and approval, and then continues through change control and periodic review.<\/p>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2591\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2591\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What are the main steps in CSV? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2591\" class=\"elementor-element elementor-element-53272b4 e-con-full e-flex e-con e-child\" data-id=\"53272b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<p class=\"e-7c5469b-fa0a008 e-paragraph-base e-default-p\" data-interaction-id=\"7c5469b\">Common steps are defining intended use, assessing risk, setting requirements and a plan, reviewing supplier evidence, testing, managing deviations and traceability, and approving a summary report. Companies adapt this sequence to their procedures.<\/p>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2592\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2592\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Which documents are required for computer system validation? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2592\" class=\"elementor-element elementor-element-4ea118a e-con-full e-flex e-con e-child\" data-id=\"4ea118a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<p class=\"e-4875632-d5b253c e-paragraph-base e-default-p\" data-interaction-id=\"4875632\">Typical documents include a validation plan, URS, risk assessment, test evidence, traceability matrix, deviation records, and a summary report. The exact set depends on system complexity, risk, supplier evidence, and the company\u2019s quality system.<\/p>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2593\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2593\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How does GAMP 5 support risk-based CSV? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2593\" class=\"elementor-element elementor-element-3852fd5 e-flex e-con-boxed e-con e-child\" data-id=\"3852fd5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"00e0c1f\">GAMP 5 is an ISPE industry guidance that scales validation effort to system category, complexity, and risk. It helps teams apply critical thinking, but it does not replace regulatory requirements such as Part 11 or Annex 11.<\/p>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2594\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2594\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How often should a validated computerized system be reviewed or revalidated? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2594\" class=\"elementor-element elementor-element-007ed69 e-flex e-con-boxed e-con e-child\" data-id=\"007ed69\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<p class=\"e-2c57ee1-1ef562c e-paragraph-base e-default-p\" data-interaction-id=\"2c57ee1\">There is no universal fixed interval. Review or revalidation depends on changes, risk, system performance, and your procedures. Periodic reviews check the validated state, and significant changes may trigger targeted retesting.<\/p>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<h2 data-interaction-id=\"bcd6b56\" class=\"e-heading-base e-default-h2\"><\/h2>\n\t\t\t\t\t<h2 data-interaction-id=\"90fefce\" class=\"e-heading-base e-default-h2\"><\/h2>\n\t\t\t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"8cfb9a7\"><\/p>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fd7f1d6 e-flex e-con-boxed e-con e-parent\" data-id=\"fd7f1d6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cb6a87c elementor-widget elementor-widget-text-editor\" data-id=\"cb6a87c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<div style=\"width:100%;margin:32px 0;border:1px solid #D6E9E6;border-radius:10px;overflow:hidden;background:#FFFFFF;font-family:inherit\">\n\n  <div style=\"padding:24px 26px;background:linear-gradient(115deg,#E0F3F0 0%,#F4FAF9 100%);border-bottom:1px solid #D6E9E6\">\n    <p style=\"margin:0 0 8px;color:#37877D;font-size:12px;line-height:1.5;font-weight:700;letter-spacing:1.3px;text-transform:uppercase\">\n      NEED EXPERT SUPPORT?\n    <\/p>\n    <h3 style=\"margin:0;color:#234E49;font-size:23px;line-height:1.45;font-weight:700\">\n      Looking for CSV\/CSA Support for Your Pharma Systems?\n    <\/h3>\n  <\/div>\n\n  <div style=\"padding:24px 26px 26px;background:#FFFFFF\">\n    <p style=\"margin:0 0 20px;color:#52635F;font-size:16px;line-height:1.8\">\n      Contact IncepBio to discuss your computer system validation requirements and the support your project may need.\n    <\/p>\n\n    <a href=\"https:\/\/www.incepbio.com\/csa-csv\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-block;padding:12px 20px;background:#009C8D;color:#FFFFFF;text-decoration:none;font-size:15px;font-weight:600;line-height:1.5;border-radius:5px\">\n      Explore CSV\/CSA Services &rarr;\n    <\/a>\n  <\/div>\n\n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-097925c e-flex e-con-boxed e-con e-parent\" data-id=\"097925c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-71600ef elementor-widget elementor-widget-text-editor\" data-id=\"71600ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t\n<div style=\"width:100%;margin:28px 0 20px;padding-top:18px;border-top:1px solid #DCE6E5;font-family:inherit\">\n\n  <h3 style=\"margin:0 0 12px;color:#234E49;font-size:18px;line-height:1.5;font-weight:700\">\n    Related Articles\n  <\/h3>\n\n  <ul style=\"margin:0;padding-left:20px;color:#009C8D;font-size:15px;line-height:1.9\">\n    <li style=\"padding-left:3px;margin-bottom:7px\">\n      <a href=\"https:\/\/incepbio.com\/blog\/digital-validation-software-pharma\/\" style=\"color:#008F82;text-decoration:underline\">\n        Digital Validation Software: 7 Problems with Manual Validation in Pharma\n      <\/a>\n    <\/li>\n    <li style=\"padding-left:3px;margin-bottom:7px\">\n      <a href=\"https:\/\/incepbio.com\/blog\/incepone-compliance-software\/\" style=\"color:#008F82;text-decoration:underline\">\n        IncepOne Compliance Software: 7 Ways It Supports Pharma Validation\n      <\/a>\n    <\/li>\n    <li style=\"padding-left:3px;margin-bottom:0\">\n      <a href=\"https:\/\/incepbio.com\/blog\/pharmaceutical-cqv\/\" style=\"color:#008F82;text-decoration:underline\">\n        7 Key Steps in Pharmaceutical CQV\n      <\/a>\n    <\/li>\n  <\/ul>\n\n<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>\u2713 QUICK ANSWER Computer System Validation (CSV) What Is the Computer System Validation Process? The computer system validation process is a documented, risk-based approach to demonstrating that a computerized system performs as intended and meets applicable GMP and business requirements. |&nbsp; KEY STAGES Planning \u2192 Requirements \u2192 Risk Assessment \u2192 Testing \u2192 Reporting \u2192 Ongoing [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":252,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-244","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/posts\/244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/comments?post=244"}],"version-history":[{"count":8,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/posts\/244\/revisions"}],"predecessor-version":[{"id":255,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/posts\/244\/revisions\/255"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/media\/252"}],"wp:attachment":[{"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/media?parent=244"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/categories?post=244"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/incepbio.com\/blog\/wp-json\/wp\/v2\/tags?post=244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}